Acquisition
Get first
impression
Check current lighting
Check state of Installation
Picture your customer
Show the difference
Dedicated Application Bundle
Tune your offer with TCO
Lighting University
Home
Car Park
Corridor
Open Plan Office
Industry Low-Bay
Small Storages
Small Bakery
Small Butchery
Classroom
Restroom
Application Bundles
- Training Tool
Industry Low-Bay
Get first
impression
Check current lighting
Check state of Installation
Picture your customer
Show the difference
Dedicated Application Bundle
Tune your offer with TCO
Check the current lighting
1 - Measure (in accordance with the standard EN 12464-1; 2011)
Measure illuminance:
1.
On working plane (horizontal)
Illuminance E
m
≥ 300 Lux
2.
In between two luminaires, on floor level
Philips recommended ≥ 250 Lux
3.
Under a luminaire, at floor level
Philips recommended ≥ 250 Lux
4.
Wall (vertical plane)
Minimum = 50 Lux
Philips recommended ≥ 75 Lux
Read more about:
Why measure?
Using lux meter
Illuminance
1
2
3
4
Read more about:
Why measure?
Using lux meter
Illuminance
Get Certified!
Next
Previous